Thứ Năm, 21 tháng 8, 2014

Bernstein 614.2200.765 D-SU2 VKS 90GRP


MTS Replacement sensor for LD2-S-B-R-PT-02-M600-2-A0-LF2 
LD-S-B-R-PT-02-M0600-2-A0-L2 sensor
>"S" - Rod style : Fitting flange
>"B" - Electronics housing style : Bottom cable entry
>"R" - Cable type : Pigtailed
>"PT" - Integral cable
>"02" - Cable length : 2 m
>"M0600" - Stroke : 600 mm
>"2" - Input voltage : +24Vdc(+20%, -10%)
>"A0" - Output : analog (4 - 20mA)
>"L2" - Integral cable length of sensor rod : 400mm
Magnet 
>P/N : 201542-2
* Other types are available
MTS Replacement sensor for LD-S-B-R-PT-01-M0800-2-A0-L2 
LD-S-B-R-PT-02-M0800-2-A0-L2 sensor
>"S" - Rod style : Fitting flange
>"B" - Electronics housing style : Bottom cable entry
>"R" - Cable type : Pigtailed
>"PT" - Integral cable
>"02" - Cable length : 2 m
>"M0600" - Stroke : 600 mm
>"2" - Input voltage : +24Vdc(+20%, -10%)
>"A0" - Output : analog (4 - 20mA)
>"L2" - Integral cable length of sensor rod : 400mm
Magnet 
>P/N : 201542-2
* Other types are available
MTS Replacement sensor for LD2-S-B-3-R-PT-02-M900-2-A0
LD-S-B-R-PT-02-M0900-2-A0-L2 sensor
>"S" - Rod style : Fitting flange
>"B" - Electronics housing style : Bottom cable entry
>"R" - Cable type : Pigtailed
>"PT" - Integral cable
>"02" - Cable length : 2 m
>"M0900" - Stroke : 900 mm
>"2" - Input voltage : +24Vdc(+20%, -10%)
>"A0" - Output : analog (4 - 20mA)
>"L2" - Integral cable length of sensor rod : 400mm
Magnet 
>P/N : 201542-2
* Other types are available
  LD2-S-B-R-PT-02-M600-2-A0 L2F
 
'LD-S-B-R-'PT-01-M800-'2-A0-L2
 
LD2-S-B-3R-PT-02-M900-2-A0
SIKA Model: VH780EI            
Material: ST/ ST
Pipe size: DN150 (insert type)
Target plate: 29x167. shortened
Max contact rating: 250VAC@Max 15 A
Max pressure: 20bar
Medium temp: 120oC
Protect rating: IP65
Connection size: 1”BSP
SIKA Model: VH780EI            
Material: ST/ ST
Pipe size: DN150 (insert type)
Target plate: 29x167. shortened
Max contact rating: 250VAC@Max 15 A
Max pressure: 20bar
Medium temp: 120oC
Protect rating: IP65
Connection size: 1”BSP
Mitsubishi A2A CPU-S1
Mitsubishi A2A CPU
Mitsubishi A2N CPU
Mitsubishi A3A CPU
Schenck VIBROCONTROL 1000, Type CV-110 
Measuring and Monitoring Unit. Power Supply
230/115 VAC, with customer
defined settings Monitoring of
absolute bearing vibrations
Yakawa YAKAWA SERVO MOTOR
- SGMGH-20ACA61
- SGDM-20ADA
(SGMGH-20ACA61 SGDM-10ADA full set)
Torque: 11.5N.m
Power: 1800
Speed: 1500
Encoder: 3600EC
Baumer Bourdon Haenni Pressure Gauge 0-60bar
DRO 63/811.133/115E
Replaced by MEX3 D31 B29 + 0751 (0-60bar, liquid filled)
Baumer Bourdon Haenni Pressure Gauge ( For Gas R404A: -1 đến 12 bar; -50 đến 28oC)
DRO 80/331.111/460
Baumer Bourdon Haenni Pressure Gauge ( cho gas R404A: -1 đến 24 bar; -50 đến 50oC)
DRO 80/331.111/470
Baumer Bourdon Haenni Pressure Gauge 0- 2.5bar
DRC 100/811.133/045E
Replaced by MEX5 D31 B18 + 0751 (0-2.5bar, liquid filled)
Baumer Bourdon Haenni Pressure Gauge 0-1.6bar
DRO 63/412.111/035C
Replaced by MEX3 D31 B16 + 0751 (0-1.6bar, liquid filled)
Baumer Bourdon Haenni Pressure Gauge 0-60bar
DRO 63/811.133/115E
Replaced by MEX3 D31 B29 + 0751 (0-60bar, liquid filled)
Baumer Bourdon Haenni Pressure Gauge ( For Gas R404A: -1 đến 12 bar; -50 đến 28oC)
DRO 80/331.111/460
Baumer Bourdon Haenni Pressure Gauge ( cho gas R404A: -1 đến 24 bar; -50 đến 50oC)
DRO 80/331.111/470
Baumer Bourdon Haenni Pressure Gauge 0-1.6bar
DRO 63/412.111/035C
Replaced by MEX3 D31 B16 + 0751 (0-1.6bar, liquid filled)
Crydom_Crouzet D53TP50D / SSR Crydom 
Three-Phase SCR AC Switch 
Output with LED Status Indicator / Line
Voltage: 48~530Vrms, 
Load Current: 0.05~50Arms, 
Control Voltage: 3~32Vdc, 
3 Phase Controlled, 
Zero Cross Switching,
Surge Current 1-Cycle: 625Apk
Bernstein 614.2200.765 D-SU2 VKS 90GRP
Limit switches; instead of D-SU2 UKS; Part no: 614.2200.765
Bernstein 614.2200.765 D-SU2 VKS 90GRP
Limit switches; instead of D-SU2 UKS; Part no: 614.2200.765
Wenglor KR87-PCT2
Wenglor KR87-PCT2
Crouzet 84873023 / MCT Crouzet C-Lynx
Phase Control Relay / MWU Type
/ Power Supply: Self-Powered 3
Phase 208~480Vac, 50/60Hz,
Control Functions: Phase Failure
and Phase Sequence
(208~480Vac, 50/60Hz),
Undervoltage (-20%~-2%),
Output Relay: 1 Single Pole
ChangeoverRelay (5A), Casing
Width: 17.5mm
Crouzet 84873023 / MCT Crouzet C-Lynx
Phase Control Relay / MWU Type
/ Power Supply: Self-Powered 3
Phase 208~480Vac, 50/60Hz,
Control Functions: Phase Failure
and Phase Sequence
(208~480Vac, 50/60Hz),
Undervoltage (-20%~-2%),
Output Relay: 1 Single Pole
ChangeoverRelay (5A), Casing
Width: 17.5mm
Micro Detectors PM1/AP-2H (PNP)_replaced by AM1/AP-2H
  SSU/00-0E
  SSG/AP-0E
  SS7/AP-1K
K is M12 right angle plug cable exit (no longer)
 
Replaced by SS7/LP-1E
E is M12 axial plug cable exit
(you can use it with a right angle plug connector CD12M/0B-***C1)

Không có nhận xét nào: